PYZX/PYXF-30A,30B,45A,45B,60A,60B,90A,90B
Precision
32*4.2
Awl
3 years
Metal
Carton Box
5000 Piece/Pieces per Month
1pc/sterilized box, 10boxes/ctn or as your required
Surgical Room
1years
Yes
White
Machinery
Online technical support
Availability: | |
---|---|
Disposable Linear Stapler introduction
The disposable linear stapler is used to close the stump or incision in the reconstruction of the digestive tract and organ resection
Clinical application on suture of the human esophagus, stomach, and duodenum.
The single-use GIA linear stapler is not designed, sold, or intended for use except as indicated.
The disposable linear stapler and reload should not be used on tissue which would not be able to tolerate conventional suture materials or conventional closure techniques.
The GIA linear stapler must not be used if the retaining pin cannot be positioned securely in the retaining pin receiving hole on the anvil. Failure to position the retaining pin may result in improperly formed staples and a compromised staple line and may cause bleeding, leakage or disruption of the staple line.
Tissue thickness should be carefully evaluated before firing any stapler.
The surgical linear stapler should not be used on organic tissues, such as liver, spleen, or kidney as compressing the tissue may be destructive.
Model | Suture Length(mm) | Height Of Nail | Color of Nail Diameter(mm) |
PYZX/PYXF-30A | 30 | 4.5 | Green |
PYZX/PYXF-30B | 3.8 | Blue | |
PYZX/PYXF-45A | 45 | 4.8 | Green |
PYZX/PYXF-45B | 3.8 | Blue | |
PYZX/PYXF-60A | 60 | 4.8 | Green |
PYZX/PYXF-60B | 3.8 | Blue | |
PYZX/PYXF-90A | 90 | 4.8 | Green |
PYZX/PYXF-90B | 3.8 | Blue |
Packaging Details:
1pc/sterilized box, 10boxes/ctn or as your required
Port:
shanghai
Quantity(Pieces) | 1 - 1000 | 1001 - 10000 | 10001 - 1000000 | >1000000 |
Est. Time(days) | 15 | 20 | 25 | To be negotiated |
1. Check the aseptic packaging of the device, open the package and take out the device after confirming that it is not damaged;
2. Remove the red staple cartridge protective cover on the instrument;
3. Place the instrument on the part to be sutured, and push the positioning needle forward to make it enter the positioning hole correctly; Note: If the positioning needle cannot enter the positioning hole correctly, please carefully check whether the installation of the components is correct.
4. For a single firing of the handle, please always keep a good field of vision during the closing of the instrument, organize the tissues to avoid surrounding tissues or organs being caught in the instrument, and check the arrow on the handle of the positioning rod push plate “&uarr ;”Whether it is aligned with the black marking line on the fixed handle; if the alignment is not correct, push the positioning pin forward to make it aligned;
5. Firing the handle twice, clamp the tissue to be removed, and return the handle to its original position;
6. Fire the handle again to complete the tissue suture (just hold the firing handle to the end);
7. Before exiting the instrument, use a scalpel to remove the excess tissue that needs to be removed;
8. Press the reset button to exit the instrument.
9. If you need to replace the components, first confirm that the firing handle is reset, pull the positioning rod push plate handle to the bottom end, and remove the previously used components; take out the spare components from the aseptic package, install the components on the instrument, and check the positioning Whether the needle can enter the positioning hole, pull the positioning rod push plate and the positioning needle can slide up and down, indicating that the component is installed in place, remove the red protective cover on the component, and repeat steps 3~8.
Linear Stapler Uses :
The disposable linear stapler has applications in abdominal, gynecological, pediatric and thoracic surgical procedures for resection or transection of tissue.